86 220BW8plus LCD Safety Test Requirements

Allunits that are returned for service or repair must pass the
originalmanufactures safety tests. Safety testing requires both
Hipotand Ground Continuity testing.
HI-POT TEST INSTRUCTION

1.Applicationrequirements

1.1 Allmains operated products must pass the Hi-Pot test as
describedin this instruction.
1.2 Thistest must be performed again after the covers have
beenrefitted following the repair ,inspection or modification
ofthe product.

2. Test method

2.1 Connectingconditions
2.1.1 The test specified must be applied between the parallel-
bladeplug of the mainscord and all accessible metal
partsof the product.
2.1.2 Before carrying out the test, reliable conductive
connectionsmust be ensured and thereafter be
maintainedthroughout the test period.
2.1.3 The mains switch(es) must be in the "ON" position.
2.2 Test Requirements
Allproducts should be HiPot and Ground Continuity tested as
follows:
2.2.1 The minimum test duration for Quality Control Inspector
mustbe 1 minute.
2.2.2 The test voltage must be maintained within the specified
voltage+ 5%.
2.2.3 There must be no breakdown during the test.
2.2.4 The grounding blade or pin of mains plug must be
conductedwith accessible metal parts.

3.Equipments and Connection

3.1.Equipments
Forexample :
-Zentech 9032 PROGRAMMABLE AUTO SAFETY
TESTER
3.2.Connection

4.Recording

Hipotand Ground Continuity testing records have to be kept
fora period of 10 years.
*T urn o n t he powers witch o f monitorbefore Hipota nd
Gr o un d Con tin ui ty tes tin g.
Connect theclip to themonitor.
Clip
(Rea r vie w of monitor)
Connectthepowercord
tothe monitor.
Power outlet
(Zentech 9 032 tes ter)
Condition Hi-PotTest for
productswhere
themains input
is220V AC
Hi-PotTest for
productswhere
themains input
is110V AC
GroundContinuity
Testrequirement
Test
voltage
2820VDC
(2000VAC)
1700VDC
(1200VAC)
Testtime 3seconds 1seconds
Tripcurrent
(Tester)
Setat 100uA for
Maxlimit;
Setat 0.1uA for
Minlimit.
5mA
Ramptime
(Tester)
Setat 2 seconds
Testcurrent:
25A,AC
Testtime:
3seconds
Resistancerequired:
<=0.09+Rohm,
Ris the resistance
ofthe mains cord.

90

240PW9 LCD