Philips SPX Cleaning the Lens, Safety, Cable Conductor colour codes, Brown, Blue, Neutral

Models: SPX 15-35 SPX

1 14
Download 14 pages 16.03 Kb
Page 12
Image 12
Cleaning the Lens

SPX Operation Manual

12

Cleaning the Lens

Remove the Lens Tube from the SPX.

Using a 3mm Allen Key, undo the retaining screws on the back and front of the tube.

Open the top cover on the lens tube.

As the lens is multicoated, clean with a soft cloth or lens tissue only. To remove baked-on dust use a window cleaner.

The above are the only maintenance tasks which can be safely carried out by non approved personnel. Refer below - Safety & Maintenance note.

Safety

Philips Selecon has manufactured this luminaire in accordance with recognised best practices to recommended international safety standards. It is your responsibility to maintain this luminaire in good & safe working condition.

Repairs should only be carried out by suitably qualified persons. Do not operate the luminaire with cracked lens, damaged cable, etc. Consult your Philips Selecon distributor for assistance. Only replace damaged parts with authorised Philips Selecon spares.

N.B. Luminaire Cable - Your Philips Selecon luminaire is fitted with special heat resistant flexible cable, replace with genuine Philips Selecon spare part cable kit only - refer to your Philips Selecon distributor. (Replacement cables are supplied complete with necessary terminal connectors.)

Cable Conductor colour codes:

 

Brown

- Phase, Live

Blue

- Neutral

As this luminaire is Double Insulated the Green/Yellow Earth wire may not be present and will have been cut back within the loom.

Version 1.1: 2010 © 2010 Philips Selecon All Rights Reserved