PicoScope 2104 & 2105 PC Oscilloscope User Guide
3
3.1
Technical reference
Driver
Once you have installed the PicoScope and PicoLog software, Windows will automatically install the driver when the PicoScope PC Oscilloscope is plugged in for the first time.
The Windows 98SE/ME/2000/XP/2003
3.2Driver error codes
This section is aimed at those people who intend to write their own programs for use with the driver. A description of the driver error codes is given below. If the PicoScope or PicoLog software reports an error, refer to the FAQ.
Code | Enumeration | Description |
|
|
|
0 | PS2000_OK | The PicoScope 2000 Series unit is functioning |
|
| correctly. |
1 | PS2000_MAX_UNITS_OPENED | Attempts have been made to open more than |
|
| PS2000_MAX_UNITS units. |
2 | PS2000_MEM_FAIL | Not enough memory could be allocated on the |
|
| host machine. |
3 | PS2000_NOT_FOUND | No PicoScope 2000 Series unit could be found. |
4 | PS2000_FW_FAIL | Unable to download firmware. |
5 | PS2000_NOT_RESPONDING | The PicoScope 2000 Series unit is not responding |
|
| to commands from the PC. |
6 | PS2000_CONFIG_FAIL | The configuration information in the oscilloscope |
|
| has become corrupt or is missing. |
7 | PS2000_OS_NOT_SUPPORTED | The operating system is not one of the supported |
|
| products: Windows 98SE, ME, 2000, XP and |
|
| 2003. |
|
|
|