PicoScope 2104 & 2105 PC Oscilloscope User Guide
3.3.13 ps2000_set_ets
long ps2000_set_ets ( | short | handle, |
| short | mode, |
| short | ets_cycles, |
| short | ets_interleave ) |
This function is used to enable or disable ETS (equivalent time sampling) and to set the ETS parameters.
Arguments
handle, the handle to the required device.
mode:
-PS2000_ETS_OFF (0) - disables ETS,
-PS2000_ETS_FAST(1) - enables ETS and provides ets_cycles of data, which may contain data from previously returned cycles,
-PS2000_ETS_SLOW (2) - enables ETS and provides fresh data every
ets_cycles cycles. This takes longer to provide each data set, but the data sets are more stable and are unique.
ets_cycles, specifies the number of cycles to store: the computer can then select ets_interleave cycles to give the most uniform spread of samples. ets_cycles should be between two and five times the value of ets_interleave.
ets_interleave, specifies the number of ETS interleaves to use. If the sample time is 20 ns and the interleave 10, the approximate time per sample will be 2 ns.
Returns
If ETS is enabled, the effective sample time will be returned.
0 if ETS is disabled or one of the parameters is out of range.