CLD-V5000 Level III • Chapter Three

14) SPEED SET LD (CAV Only)

Function:

Speed for Multi-Speed playing is specified.

 

Format:

Integer

S P

 

 

 

Explanation:

Contents of the Speed Register are rewritten with this command.

 

 

Immediately, the completion status is returned. The active mode

 

 

of the player does not change. This command is accepted even

 

 

when Multi-Speed Mode is in effect.

 

 

 

 

The speed parameter indicates the number of fields moved per

 

 

second, and it is specified in range from 1 to 255. It is 60 (with a

 

 

range from 45 to 90) for normal play. The initial value is 60.

 

 

The relationship between representative play speeds and

 

 

parameters is as follows:

 

 

 

 

 

 

 

 

 

 

 

 

Integer

Possible range

 

Speed

Integer

Possible range

Speed

 

 

of integers

 

 

 

of integers

 

 

 

 

 

 

 

 

 

 

180

150-255

 

X3

15

12-22

1/4

 

120

91-149

 

X2

7

6-11

1/8

 

 

 

 

 

 

 

 

 

60

46-90

 

X1

4

3-5

1/16

 

 

 

 

 

 

 

 

 

30

23-45

 

1/2

2

0-2

Step 1*

 

 

 

 

 

 

 

 

Figure 3-H

These integers provide compatibility with LD-V8000, LD-V4400 and the LD-V2200. Programs written for the LD-V8000 or LD-V4400 using the Òrange of integersÓ in column two will play on the CLD-V5000, CLD-V2800/2600/2400 at the corresponding speeds in column one.

Execution:

*

Play Mode

 

 

3 0 S P M F <C/R>

R <C/R>

 

*

1/2 speed Multi-Speed play

 

15 S P <C/R>

R <C/R>

*1/4 speed Multi-Speed play

*NOTE: 2SP plays one frame every second (Step 1) on the CLD-V5000, and on the CLD-V2800/2600/2400. Similarly, 2SP sets a Step 1 to play one frame every second on the Pioneer LD-V2200, LD-V4400 and LD-V8000. Early versions of the CLD-V2400 played 1 frame every three seconds (Step 3) if a 0SP or 1SP were sent to the player. Later production units of the CLD-V2400, however, all play Step 1 if a 0SP, 1SP or 2SP is sent to the player. To achieve compatibility across the player line for a one frame per second playback speed, send the 2 SP command, followed by MF (Multi-Speed Forward). On the CLD-V5000, STEP 3 is only available using the Remote Control Unit.

CLD-V5000 Level III UserÕs Manual TP 120 v. 1.0 • 1/96