48) REGISTER E SET |
| LD/CD |
|
|
|
|
|
|
|
| |||||
Function: |
|
|
|
| Changes the current setting of Register E. (Repeat) |
|
|
|
| ||||||
Format: |
|
|
|
| Integer | R E |
|
|
|
|
|
|
|
| |
Explanation: |
|
|
|
| When power is turned ON, and SW 4 is set ON/DOWN, the Repeat | ||||||||||
|
|
|
|
| Function of Register E is set to 1/ON. When Switch 5 is ON/DOWN | ||||||||||
|
|
|
|
| the Both Sides Function of Register E is set to 1/ON. Register E | ||||||||||
|
|
|
|
| sets the Repeat Mode, as follows: To set the Function ON, input the | ||||||||||
|
|
|
|
| value indicated by the Integer. To set several, add up the Integers. | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Integer |
| Function |
|
| 1 |
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
| Repeat |
|
| ON | OFF |
|
| ||||||
| 2 |
| Both Sides |
| ON | OFF |
|
| |||||||
| 4 |
| (Not Used) |
|
|
|
|
|
|
|
| ||||
| 8 |
| (Not Used) |
|
|
|
|
|
|
|
| ||||
| 16 |
| (Not Used) |
|
|
|
|
|
|
|
| ||||
| 32 |
| (Not Used) |
|
|
|
|
|
|
|
| ||||
| 64 |
| (Not Used) |
|
|
|
|
|
|
|
| ||||
| 128 |
| (Not Used) |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Figure |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| Repeat Mode |
| Repeat |
| Both Sides |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| Stops after playing back one side | OFF |
| OFF |
| |||||||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
| Stops after playing back both sides | OFF |
| ON |
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
| ON |
| OFF |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
| ON |
| ON |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Figure |
|
|
|
|
|
|
|
|
|
|
Execution: |
|
|
|
| * Initial value 0 |
|
|
|
|
|
|
|
| ||
|
|
|
|
| 2 R E <C/R> | R <C/R> |
|
|
|
|
|
|
|
* Repeat is OFF,
NOTE: When Repeat Mode is changed using the REPEAT key of the Remote Control Unit or Front Panel, the contents of Register E change as follows:
Screen Display | RegisterE Contents |
All Repeat | 00000011 |
Side Repeat | 00000001 |
Chapter Repeat | 00000001 |
Auto Return | 000000X0 |
|
|
Also: The Repeat of Register C and that of Register E are always linked. Each changes according to any change in the contents of the other.