Read CD MSF

2.23Read CD MSF (B9h)

IMPORTANT: This command applies only to models DRM-602X, DRM-624X, DR-U124X, DR-UA124X

The Starting M field, the Starting S field, and the Starting F field specify the absolute MSF address at which the Read operation shall begin.

The Ending M field, the Ending S field, and the Ending F field specify the absolute MSF address where the Read operation shall end. All contiguous sectors between the starting and the ending MSF address shall be read.

A starting MSF address equal to an ending MSF address prevents a read operation. This shall not be considered an error. If the starting MSF address is greater than the ending MSF address, the command shall be terminated with Check Condition status. The sense key shall be set to

ILLEGAL REQUEST.

If the starting address is not found, or if a not ready condition exists, the command shall be terminated with Check Condition status.