Read(6)

2.18Read(6) (08h)

Operation Code is (08h).

This six-byte READ command only allows reads of up to 255 blocks.

The logical blocks will have the length set by MODE SELECT or the power-on default. For longer reads, use the ten-byte READ(10) command.

After a read operation, the drive holds the head at the last read track until an inactivity time-out occurs.