4. TROUBLESHOOTING

4.1. POWER FAILURE

If electric power is removed for any reason, the appliance will shut down To restart the appliance, follow the appliance start up procedure in section 2.2.

4.2. HIGH TEMPERATURE LIMIT

This appliance is equipped with a high temperature limit switch. The high temperature limit switch will stop the appliance from functioning if the internal cook tank reaches an unsafe temperature. In the event that the high temperature limit has tripped, Please refer to the following procedure to reset the switch.

1.Turn the appliance off.

2.Allow the appliance ample time to cool to room temperature.

3.Add water to the cook tank as needed.

4.Press the high temperature reset button if equipped.

5.The high limit switch is now reset and the appliance is ready for start up.

High Temperature Reset Button

(Not on all models)

WARNING

DO NOT add water to the tank until it has been given ample time to cool down. Failure to do so may result in damage to the appliance and/or injury to the operator.

4.3. DRAIN VALVE INTERLOCK

If your appliance is equipped with a drain valve interlock circuit, the appliance will stop heating if the tank drain valve is opened. In some cases the appliance will turn off. Refer to the following procedure to resume operation after the drain valve interlock is tripped.

1.Turn the appliance OFF (if not already OFF).

2.Close the tank drain valve and fill the tank with water.

3.Turn the appliance ON.