To Access Electrical Connections

INSTALLATION

WARNING

DO NOT attempt to connect the appliance to an electrical supply other then that indicated on the data plate. Electrical connection should be performed by qualified personnel.

WARNING

The electrical connection used by this appliance must comply with local codes. If there are no local codes that apply, refer to the National Electrical Code (NEC), ANSI/NFPA 70 for installation in the US. In Canada, refer to CSA Standard C22.2 and local codes. In all other cases, refer to local and national codes and regulations.

WARNING

The appliance must be grounded in accordance with local code; if there is no local code, comply with the NEC and ANSI/NFPA No. 70 latest edition (for US and Canadian installations). In all other cases, refer to local and national codes and regulations. To comply with European requirements, European models are equipped with an equalization- bonding clamp. An equalization bonding lead must be connected to this clamp to provide sufficient protection against potential difference. This clamp, located on the rear of the appliance is marked with the following universal symbol. 1) 1” (2.54cm) Access Hole

To Access Electrical Connections

Phillips Screwdriver Required

WARNING

This equipment must be installed so that the plug is accessible unless other means for disconnection from the power supply (e.g. a circuit breaker) is provided.

WARNING

If this appliance is permanently connected to fixed wiring, it must be connected by means of copper wires having a temperature rating of not less then 167°F (75°C).

1) 1” (2.54cm) Access Hole

2) Connection Points

1/2” (1.27cm) Allen Wrench Required

3) Ground Connection

Flat head screwdriver required

 

1.6. VENTILATION AND FIRE SAFETY SYSTEMS

 

Your new appliance must have proper ventilation to function safely and properly. It is very important

 

to install a fire safety system. Your ventilation system should be designed to allow for easy cleaning.

 

Frequent cleaning and proper maintenance of the ventilation system and the appliance will reduce the

 

chances of fire. Ventilation and fire safety systems must comply to local and national codes. Refer to

 

ANSI 83.11 for a list of reference documents that will provide guidance on ventilation and fire safety

 

systems.