1.4. PLUMBING CONNECTIONS

PE14D: Floor Model Electric Pasta CookerINSTALLATION

1.4. PLUMBING CONNECTIONS

The plumbing installation should be done by a licensed plumber and must comply with local and national codes.

1.4.1.WATER INLET CONNECTIONS

If a faucet or water fill option is equipped on your appliance connections to a potable water supply will be required. If a single water connection is required it is recommended that the appliance is connected to hot water supply. This will greatly decrease the time it takes for the appliance to reach operating temperature. Prior to installation, a water treatment specialist should inspect the water supply. Water hardness should contain no more then 2.0 grains/gallon. The pH level should be between 6.5 and 8.0. These conditions can be obtained with the use of a properly maintained water softener. The incoming water pressure should be between 20 psi (1.38 bars) to 60 psi (4.14 bars). For higher water pressures, a high-pressure regulator must be installed to inlet plumbing to avoid damage caused by water hammer. The maximum allowable incoming water temperature is 180°F (82°C). Have your water tested and record the measured values below.

Temperature Hardness pH Pressure

Water Quality Checklist

 

Measured

Range

OK

 

180°F (82°C) Max.

 

 

2.0 Grains/Gal. Max.

 

 

6.5 to 8.0

 

 

20 psi to 60 psi

 

WARNING When water is at a high temperature and high pressure, excessive splashing of hot water may occur that could result in injury.

1.4.2.DRAIN CONNECTIONS

Each tank has a drain that can be inserted into a drainage system. Each tank also has an overflow line. The overflow connection is after the drain valve to provide an unobstructed overflow path. The drain and overflow line for each tank may be connected together to form a common drain line.

1.5.ELECTRICAL CONNECTIONS

It is advised that this power supply be plugged into a wall receptacle that is controlled by the ventilation control. This will prevent the appliance from being operated without the ventilator on. If your appliance requires an electrical connection, the power requirements are listed below.

Voltage/Phase

KW

Amps

200VAC, single phase

11.6

58

208VAC, single phase

12.5

60

220VAC, single phase

11.4

52

240VAC, single phase

12.5

52

200VAC, three phase

11.6

33

208VAC, three phase

12.5

35

220VAC, three phase

11.4

30

240VAC, three phase

12.5

30

346/200VAC, three phase

11.6

19

380/220VAC, three phase

11.4

17

400/230VAC, three phase

12.5

18

415/240VAC, three phase

12.5

17

WARNING

All copper wiring for this appliance must be made in accordance with the wiring diagram(s) located on the appliance.

CAUTION

Connecting the appliance to the wrong power supply may damage the appliance and void the warranty.

WARNING

A country approved all pole circuit breaker with a minimum open contact gap of 3mm must be used for proper installation. (CE countries)

WARNING

This appliance must be connected to a power supply having the same voltage and phase as specified on the data plate located on the inside of the appliance door.