When an Indicator is Lit or Flashing

The indicators on the projector’s control panel light or flash to notify of problems, as described below.

An indicator is also used to notify you of the currently set power mode (under normal circumstances). See “Power Cable Con- nections and Switching the Power On/Off” on page E-23.

STATUS indicator

STANDBY indicator

STATUS

STANDBY

STANDBY

AUTO

 

Indicator status

What you should do

 

 

 

STATUS

Lit red

It is time to replace the lamp.

 

 

 

When the power is on (Lit green)

Replace with a new lamp cartridge.

 

 

STANDBY

Standby (Lit amber)

 

 

 

 

 

 

The lamp has reached the end of its service life.The power

STATUS

Lit red

will no longer turn on.

 

 

The projector can be used for 100 hours after the lamp has

 

Flashing amber for 60 seconds, then lit

reached the end of its service life.

 

Replace with a new lamp cartridge.

STANDBY

amber

 

 

 

 

 

STATUS

Flashing red

The lamp cover is open.

 

(lit for 1 seconds/off for 1 seconds)

The lamp cover is not properly mounted. Mount it properly.

STANDBY

Lit red

 

 

 

 

 

 

The temperature is abnormally high.

 

Flashing red

• The temperature protector has been activated. If the room

STATUS

temperature is high, move the projector to a cool place. If

 

(lit for 0.5 seconds/off for 0.5 seconds)

the projector’s internal temperature is high, check the cool-

STANDBY

Lit red

ing fan’s ventilation slots and clean them if they are clogged.

• When the temperature protector is activated, the power turns

 

 

 

off and in some cases will not turn back on immediately. In

 

 

this case wait about 90 seconds, then try again.

 

 

 

STATUS

Flashing red

The fan has stopped.

 

(lit for 0.5 seconds/off for 0.5 seconds)

Unplug the power cable and contact a store that sells the

 

Lit amber

U5-732 for repairs.

STANDBY

 

 

 

 

 

Flashing red

The lamp will not light.

STATUS

(lit for 1 seconds/off for 1 seconds)

Wait at least 90 seconds, then turn the power back on. If the

 

When the lamp has burned out during use

problem persists, unplug the power cord and contact a store

 

that sells the U5-732 for repairs.

STANDBY

Flashing amber for 90 seconds, then lit amber

When the lamp does not come on from the start

 

 

 

 

Lit amber

 

 

 

 

Should an indicator be in a condition other than normal or flash at a rate other than the aforementioned, disconnect the power cable and contact your store of purchase.

Thermal Protector

When the temperature inside the projector becomes abnormally high, the STATUS indicator flashes red (0.5 seconds on/0.5 seconds off), the STANDBY indicator is a steady red, and at the same time the temperature protector operates and switches off the power of the projector.

Should this happen, please take the following actions.

1.Switch off the power and disconnect the power plug from the wall outlet.

2.Check the following matters and take the required measures.

When the projector is being used in a location that has a high ambient temperature, set it up again in a cool location. Check the outflow and intake holes and clean them if they are obstructed.

3.Wait about 60 minutes until the temperature of the projector drops.

If after having performed the above matters, the problem still has not been solved, please contact your store of purchase.

E-61

Page 61
Image 61
PLUS Vision U5-732 user manual When an Indicator is Lit or Flashing, Thermal Protector