32In the Fast Configuration Wizard - System Flags dialog box, enter the following information:

Flag

Value

 

 

 

 

Conference ID

The number of digits of the Conference ID that will be

Length (MCU)

assigned by the MCU.

 

 

Range: 2-16 (Default: 5)

 

 

Note: Selecting 2 digits limits the number of

 

simultaneous ongoing conferences to 99.

 

 

 

Minimum

The minimum number of digits that

Selecting 2

Conference ID

the user must enter when

Length (User)

manually assigning a numeric ID

digits limits the

 

to a conference.

number of

 

Range: 2-16 (Default: 4)

simultaneous

 

 

ongoing

Maximum

The maximum number of digits

conferences to

Conference ID

that the user can enter when

99.

Length (User)

manually assigning a Numeric ID

 

 

to a conference.

 

 

Range: 2-16 (Default: 8)

 

 

 

 

MCU Display Name

The MCU name that appears at the endpoints.

 

Default: Polycom RMX 2000

 

 

 

 

Terminate

Yes/No (Default: Yes)

 

Conference when

 

 

Chairperson Exits

 

 

 

 

Auto Extend

When Yes is selected (default) allows conferences

Conferences

running on the RMX to be automatically extended as

 

long as there are participants connected and there are

 

available resources.

 

 

 

 

These flags can be modified later, if required, via the Setup menu’s System Configuration option. For more information, see the