Air Compressor Pump (not shown): Compresses air into the air tank. Working air

is not available until the compressor has raised the air tank pressure above that

required at the air outlet.

 

 

Drain Valve: The drain valve is located at the base of the

 

 

air tank and is used to drain condensation at the end of

 

 

each use.

Drain

 

Check Valve: When the air compressor is operating, the

 

Valve

 

check valve is "open", allowing compressed air to enter

 

 

 

 

the air tank. When the air compressor reaches "cut-out" pressure, the check

valve "closes", allowing air pressure to remain inside the air tank.

Pressure Release Valve: The pressure

 

Pressure

release valve located on the side of the

Release

pressure switch, is designed to

Valve

automatically release compressed air from

 

the compressor head and the outlet tube

 

when the air compressor reaches "cut-out"

 

pressure or is shut off. The pressure

 

release valve allows the motor to restart

 

freely. When the motor stops running, air

 

will be heard escaping from this valve for a

 

few seconds. No air should be heard

 

leaking when the motor is running or after

 

the unit reaches "cut-out" pressure.

 

Motor Overload Protector: The motor has

a thermal overload protector. If the motor overheats

for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. To restart:

1.Set the Auto/Off switch to "Off" and unplug unit.

2.Allow the motor to cool.

3.Depress the red reset button on the motor.

4.Plug the power cord into the correct branch circuit receptacle.

5.Set the Auto/Off switch to "Auto" position.

Air Intake Filter (not shown): This filter is designed to clean air coming into the pump. This filter must always be clean and ventilation openings free from obstruc- tions. See Maintenance.

How to Use Your Unit

How to Stop

Set the Auto/Off switch to "Off".

Before Starting

Do not operate this unit until you read this instruction manual for safety, operation and maintenance instructions.

Break-in Procedure

Risk of property damage. Serious damage may result if the following break-in instructions are not closely followed.

This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.

1.Make sure the Auto/Off switch is in the "Off" position.

2.Check oil level in pump. See Oil paragraph in the Maintenance section for instructions.

16- ENG­

Page 16
Image 16
Porter-Cable Air Compressor Pressure Release Valve The pressure, Motor Overload Protector The motor has, How to Stop