ACCESSORIES

Since accessories, other than those offered by PORTER-CABLE, have not been tested with this product, use of such accessories with this tool could be haz- ardous. To reduce the risk of injury, only PORTER-CABLE recommended accessories should be used with this product.

A complete line of accessories is available from your PORTER-CABLE Factory Service Center or a PORTER-CABLE Authorized Warranty Service Center. Please visit our Web Site www.deltaportercable.com for a catalog or for the name of your nearest supplier.

TROUBLESHOOTING

Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.

PROBLEM

CAUSE

 

 

 

CORRECTION

Excessive

Pressure switch does

 

Move Auto/Off lever to the "Off"

tank pressure

not shut off motor when

 

position, if the unit does not shut off

- safety valve

compressor reaches

 

contact a Trained Service Technician.

pops off

"cut-out" pressure.

 

 

 

 

 

 

Pressure switch "cut-

 

Contact a Trained Service Technician.

 

out" too high.

 

 

 

 

 

Air leaks at

Tube fittings are not

 

Tighten fittings where air can be

fittings

tight enough.

 

heard escaping. Check fittings

 

 

 

with soapy water solution. DO

 

 

 

NOT OVER TIGHTEN.

Air leaks at

Check valve seat

 

A defective check valve results in

or inside

damaged.

 

a constant air leak at the pressure

check valve

 

 

release valve when there is pressure in

 

 

 

the tank and the compressor is shut

 

 

 

off. Replace check valve. Refer the To

 

 

 

Replace or Clean Check Valve in

 

 

 

the Service and Adjustments section.

Air leaks at

Defective pressure

 

Contact a Trained Service Technician.

pressure switch

switch release valve.

 

 

 

 

 

release valve

 

 

 

 

 

 

Air leaks in air

Defective air tank.

 

Air tank must be replaced.

tank or at air

 

 

Do not repair the leak.

tank welds

 

 

 

 

 

Risk of bursting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not drill into, weld or otherwise

 

 

 

modify air tank or it will weaken. The

 

 

 

tank can rupture or explode.

Air leaks

Leaking seal.

 

Contact a Trained Service Technician.

between head

 

 

 

 

 

 

and valve plate

 

 

 

 

 

 