SERVICE AND ADJUSTMENTS
ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN.
Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to
voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.
To Replace Regulator
1.Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section.
2.Unplug outfit.
3.Using an adjustable wrench remove the gauges and quick connect from the regulator.
4.Remove the regulator.
5.Apply pipe sealant tape to the nipple on the pressure switch.
6.Assemble the regulator and orient as shown.
NOTE: Arrow indicates flow of air. Make sure it is pointing in the direction of air flow.
7.Reapply pipe sealant to gauges and quick connect.
8.Reassemble gauges and quick connect. Orient gauges to read correctly. Tighten quick connect with wrench.
Regulator
Arrow
19- ENG | D29795 |