STARTING WATTAGE REQUIREMENTS

3.The running wattage of examples 1 & 2 totals 1150 watts. The starting wattage of the small refrigerator is 2000 watts which is 1500 watts more than the running watts. Take this difference of 1500 starting watts from the refrigerator and add to the total running watts of 1150.

Example 3:

1500

Starting Watts

 

1150

Running Watts

TOTAL

=2650 Total Watts

Generator must have a maximum capacity of at least 2650 watts.

STARTING WATTAGE REQUIREMENTS

1.Some appliances and tools will list on the motor nameplate the starting and running voltage and amperage requirements. Use the following formula to convert voltage and amperage to wattage:

Volts X Amp = Watts

Example: 120 volts x 10 amps = 1200 watts

2.To determine the approximate starting wattage requirement for most appliances and tools with inductive type motors, multiply the wattage that was calculated by 2 to 4 times to assure adequate generator capacity. If the nameplate information is not available use the values on the following chart as a guide.

3.Remember that the starting and running wattage for resistive loads are the same. (Example: a 100 watt light bulb requires only 100 watts to start.) Most resistive loads will be listed in wattage.

Application Guide

3/8” Hand Drill

Jigsaw

(1/3 HP) Airless Sprayer

6” Bench Grinder

Belt Sander

Demolition Hammer

7-1/4” Circular Saw

(Small) Air Compressor

Light Bulb

Home Security

Television

Microwave

Toaster Oven

(5,000 BTU) Portable Heater

Furnace Fan

Refrigerator/Freezer

Sump Pump

Clothes Washer

Water Heater

(30,000 BTU) Air Conditioner

(12V DC) Battery Charger

Radio

Slow Cooker

Electric Blanket

Electric Skillet

Coffee Maker

Small Refrigerator

The wattage ratings shown are averages - actual wattage may vary.

To select the right generator for your needs, total the wattage of the items to be run at the same time.

100

250

500

1000

2000

3000

4000 5000 6000 7000

8000

9000

10000

WATTAGE

 

 

Run

 

 

 

Start

 

 

 

 

 

 

 

 

 

 

23- ENG