SHUTTING DOWN
1.If you have siphoned chemicals, siphon a bucket of clean water through the chemical hose. NOTE: Failure to do so will cause damage to the pump.
2.Turn engine off. See Engine Owner’s Manual.
NOTE: NEVER turn the water off with the engine running.
Never turn water supply off while pressure wash-
er engine is running or damage to pump will result.
3.Turn water source off.
4.Pull trigger on spray gun to relieve any water pressure in hose or spray gun.
5.See Storage section in this manual for proper stor- age procedures.
MAINTENANCE
WHEN PERFORMING MAINTENANCE, YOU MAY BE EXPOSED TO HOT SURFACES, WATER PRESSURE, MOVING PARTS, OR FIRE RESULTING IN DEATH. BEFORE PER-
FORMING ANY MAINTENANCE OR REPAIR, DISCONNECT SPARK PLUG WIRE, LET ENGINE COOL AND RELEASE ALL WATER PRESSURE. THE ENGINE CONTAINS FLAMMABLE FUEL. DO NOT SMOKE OR WORK NEAR OPEN FLAMES WHILE PERFORMING MAINTENANCE.
To ensure efficient operation and longer life of your pressure washer, a routine maintenance schedule should be prepared and followed. If the pressure washer is used in unusual conditions, such as
ENGINE
1.Consult the Engine Owners Manual for the manu- facturer's recommendations for any and all main- tenance.
DAPC Axial Cam (PCH2425)
PUMP
1.Pump oil (checking and changing). Refer to the fol- lowing illustrations to identify which pump is on your pressure washer. Refer to the chart for oil type, oil capacity, and maintenance schedule (if applicable).
DAPC Radial (PCV2021)
Annovi Reverberi (PCH3030, PCH2627) | Cat (PCH3540HR) | ||
|
|
|
|
|
|
|
|
13 — ENG | D22885 |