PUMP MAINTENANCE CHART

PUMP MAINTENANCE CHART

PUMP TYPE

OIL TYPE

OIL CAPACITY

CHANGE OIL

 

 

 

First 10 hours

 

after every 50

 

 

 

 

 

 

 

 

hours

 

 

 

 

 

 

 

 

 

 

 

Annovi Reverberi (XMV)

30W non detergent

13.5 oz.

x

 

x

 

 

 

 

 

 

Annovi Reverberi (XRV)

30W non detergent

18.54 oz.

x

 

x

 

 

 

 

 

 

Annovi Reverberi (XTV)

30W non detergent

9.92 oz.

x

 

x

 

 

 

 

 

 

Annovi Reverberi (RKV)

30W non detergent

18.54 oz.

x

 

x

 

 

 

 

 

 

DAPC (axial cam)

* R&O 150

8 oz.

x

 

x

 

 

 

 

 

 

DAPC (radial)

** none

n/a

n/a

 

n/a

 

 

 

 

 

 

Cat

30W non detergent

red dot on

x

 

x

 

 

sight glass

 

 

 

 

 

 

 

 

 

* If unable to find use 30 W non detergent

 

 

 

 

** This pump requires no oil, it is an oilfree pump

 

 

 

 

 

 

 

 

 

 

NOZZLE CLEANING

If the nozzle becomes clogged with foreign materials, such as dirt, excessive pressure may develop. If the nozzle becomes partially clogged or restricted, the pump pressure will pulsate. Clean the nozzle immedi- ately using the nozzle kit supplied and the following instructions:

Multi-Reg (PCV2021):

1.Shut off the pressure washer and turn off the water supply.

2.Disconnect spark plug wire.

3.Pull trigger on gun handle to relieve any water pressure.

4.Disconnect the wand from the gun.

5.Remove the nozzle from the end of the wand with the 2mm allen wrench provided as shown.

6.Clean the nozzle using the nozzle cleaner provided or a straightened paper clip. Insert into the nozzle end and work back and forth until obstruction is removed.

7.Direct water supply into nozzle end to backflush loosened particles for 30 seconds.

8.Reassemble the nozzle to the wand. Tighten securely to prevent leaks.

9.Reconnect wand to gun and turn on water supply.

10.Start pressure washer and place wand into high pressure setting to test.

Quick Connect Turret (PCH2425, PCH2627, PCH3030, PCH3540HR):

1.Shut off the pressure washer and turn off the water supply.

2.Disconnect spark plug wire.

3.Pull trigger on gun handle to relieve any water pressure.

4.Disconnect the wand from the gun.

5.Remove any obstructions with the nozzle cleaning tool provided and backflush with clean water.

6.Direct water supply into nozzle end to backflush loosened particles for 30 seconds.

7.Reconnect wand to gun and turn on water supply.

8.Start pressure washer and place wand into high pressure setting to test.