Samsung SNB-5001 Alarm input Wiring Diagram, Electrical Resistance of Copper Wire at 20C 68F

Models: SNB-5001 SNB-7001

1 92
Download 92 pages 44.16 Kb
Page 17
Image 17

Be careful not to reverse the polarity when you connect the power cable.

-Please connect the power adapter when the installation is completed.

-As shown in the table below, you may encounter a voltage-sag depending on the wire length. If you use an excessively long wire for camera connection, the camera may not work properly.

Electrical Resistance of Copper Wire at [20°C (68°F)]

Copper Wire Gauge (AWG)

#24(0.22mm2)

#22(0.33mm2)

#20(0.52mm2)

#18(0.83mm2)

Resistance (Ω/m)

0.078

0.050

0.030

0.018

Drop Voltage (V/m)

0.028

0.018

0.011

0.006

Recommended Distance (m)

Less than 20

Less than 30

Less than 30

Less than 30

Alarm input Wiring Diagram

INSTALLATION & CONNECTION

ALARM IN

GND

1

2

(5mA sink)

English _17

Page 17
Image 17
Samsung SNB-5001, SNB-7001 user manual Alarm input Wiring Diagram, Electrical Resistance of Copper Wire at 20C 68F