PD-6548
Power over Ethernet Solutions 8 Cat. No.: 06-6860-056
1 Safety Information

1.1 General Guidelines

Read the following safety information before carrying out any installation,
removal or any maintenance procedure on the Power over Ethernet Midspan.
Warnings contain instructions that must be followed for personal and product
safety. Follow all instructions carefully.
WARNINGS
Read the Installation Instructions in Section 3 before connecting
the Power over Ethernet Midspan to its power source.
A grounded power cord must be utilized with the Midspan as
defined in paragraph 1.2.
This product relies on the building installation for short-circuit
(overcurrent) protection. Ensure that a fuse or circuit breaker no
larger than 15 A for 120 VAC, (U.S.) 10 A for 230 VAC
(international) is utilized.
Do not perform any work on the unit or connect/disconnect
cables during periods of lightning activity.
A voltage mismatch can damage the equipment and may pose a
fire hazard. If the voltage indicated on the label is different from
the power outlet voltage, do not connect the Power over Ethernet
Midspan to this outlet.
For shelf-mounted equipment, be certain that the surface is
stable and strong enough to support the equipment. Do not stack
more than two of the Power over Ethernet Midspans on a single
shelf.
Ultimate disposal of this product should be handled according to
all local laws and regulations.
The Power over Ethernet Midspan "Data" and "Data + Power"
ports are shielded RJ-45 data sockets. They cannot be used as
Plain Old Telephone Service (POTS) telephone sockets. Only
RJ-45 data connectors may be connected to these sockets.