1.2Power Cord

In the event that the power cord is replaced, the replacement must meet local requirements.

For reliable connection to an AC MAINS SUPPLY, equipment provides an appliance IEC60320 inlet for connection of a detachable power supply cord.

The power socket outlet must be located near the Midspan and be easily accessible. The only way to remove power from the unit is by disconnecting the power cord from the outlet

This unit operates under SELV (Safety Extra Low Voltage) conditions according to EN60950/IEC 950. The conditions are only maintained if the equipment to which it is connected, also operates under SELV conditions.

U.S.A. and Canada

Denmark

Switzerland

France and

Peru

U.K

ƒThe cord must be UL-approved or CSA certified.

ƒThe minimum specification for the flexible cord is:

No. 18 AWG

Type SV or SJ

Three-conductor.

ƒThe cord set must have a rated current capacity of at least 10 A.

ƒThe attachment plug must be an earth-grounding type with a NEMA 5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V) configuration.

ƒThe supply plug must comply with section 107-2-D1, standard DK2-1a or DK2-5a.

ƒThe supply plug must comply with SEV/ASE 1011.

ƒThis unit cannot be powered from IT supplies. If your supplies are of the IT type, this unit must be powered by 230 V (2P+T), via an isolation transformer with a 1:1 ratio and with the secondary connection point labeled Neutral, connected directly to ground

ƒThe Power over Ethernet Midspan is covered by General Approval, NS/G/12345/J/100003, for indirect connection to a public telecommunications system