Setting Up the Console

 

27

 

 

 

 

 

Product

Value

Information provided

 

 

 

 

 

All

EVENT LOG

Displays any event codes that may

 

 

 

have been detected by the software.

 

 

 

For more information, refer to Event

 

 

 

Log.

 

 

 

 

Event Log

The event log holds a maximum of 30 events. After the log reaches 30 events, older events are erased to make room for newer ones.

Each event log entry contains the following information:

Event number

Odometer value when the event occurred

Hour meter value at the time the event occurred

Current drawn by the motor when the event occurred (treadmill only)

The following table contains a list of events detectable by the software.

Table 5. Event log numbers and descriptions

Event

Description of Event

Number

 

 

 

00

Upper PCA memory location event

 

 

02

RAM location event

 

 

03

EEPROM checksum event

 

 

05

Depressed key at power up

 

 

09

Lower PCA memory test event

 

 

10

Line Frequency out of acceptable range

 

 

11

Watchdog (Upper PCA) low voltage power

 

 

12

Watchdog (Lower PCA) low voltage power

 

 

13

Fan at incorrect speed (version 1 treadmills)

 

 

14

Fan fail (Lower PCA)

 

 

15

AC input voltage too high

 

 

16

AC input voltage too low

 

 

20

Too many maximum power requests in one second

 

 

21

Too many maximum consecutive power requests

 

 

22

No motor pulses at start up

 

 

Page 29
Image 29
Precor P30 Console manual Event Log, Event LOG