Romar Pasta Cooker
630-ROM4
|
| Safety Information |
|
|
|
|
| Important! |
|
|
|
|
|
|
|
|
|
| |
|
| WARNING! |
|
|
| Prince Castle reserves the right to change specifications | |||
|
|
|
|
| and product design without notice. Such revisions do | ||||
| Indicates information important to the proper operation of |
|
|
| |||||
|
|
|
| not entitle the buyer to corresponding changes, | |||||
| the unit. Failure to observe may result in damage to the |
|
|
| |||||
|
|
|
| improvements, additions or replacements for previously | |||||
| equipment and/or severe bodily injury or death. |
|
|
| |||||
|
|
|
| purchased equipment. | |||||
|
|
|
|
|
|
| |||
|
| CAUTION! |
|
|
|
|
|
| |
| Indicates information important to the operation of the |
|
|
|
|
|
| ||
| unit. Failure to observe may result in damage to the |
|
|
|
|
|
| ||
| equipment. |
|
|
|
|
|
| ||
|
|
|
|
|
|
| |||
|
|
|
|
| |||||
|
| Installation |
| ||||||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| General Setup |
|
|
|
|
| This unit is completely | |||||
| completed prior to the shipment of the unit to the location. |
|
|
| shipment. All wiring and hookups shall be done without | ||||
| • | Floor drain sink located no further than 10 ft. from the |
|
|
| opening the unit. | |||
|
|
|
|
|
|
| |||
|
| intended location of the unit. |
|
|
| • | Place unit on the counter. The counter must be designed to fit | ||
| • | Electrical hookup box located no further than 5 ft. from the |
|
|
|
| the size and support the weight of the unit. | ||
|
| intended location of the unit. The box should provide three |
|
|
| • | The unit must be level to insure proper function. To level the | ||
|
| phase, 240 V protected with a |
|
|
| ||||
|
|
|
|
|
| unit, use only the adjustable leveling feet (no shims or foreign | |||
|
| terminals should be rated for gauge number |
|
|
|
| |||
|
|
|
|
|
| objects). | |||
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
| ||
| • | Dedicated water outlet with manual shut off valve no further |
|
|
| • | EPH require a minimum height of 4 in. between the counter | ||
|
| than 7 ft. from the intended location of the unit. The water |
|
|
|
| and the unit. | ||
|
| pressure should be at least 50 psi. The manual |
|
|
|
|
|
| |
|
| output has to accommodate ¾ in. NPT Hose connector. |
|
|
|
|
|
| |
| • | Supporting counter with the minimum suggested dimensions |
|
|
|
|
|
| |
|
| of 24 in. high, 28 in. deep, and 44 in. wide. The counter must be |
|
|
|
|
|
| |
|
| capable of withstanding 340 lbs (weight of unit). |
|
|
|
|
|
| |
|
|
|
|
| |||||
|
| Plumbing Connections |
| ||||||
| It is highly recommended that a licensed plumber install all |
|
| • | When connecting the steam generator | ||||
| plumbing connections. |
|
|
| ensure that the valve (provided by Prince Castle) is reachable | ||||
| All |
|
|
| (arms length) from the front of the unit. The connecting “black | ||||
| with national and local plumbing codes and health department |
|
|
| pipe” must be installed behind the unit and below the counter, | ||||
| requirements. |
|
|
| away from easy reach. The | ||||
| • | For standard water installation, connect per local plumbing |
|
|
|
| secured all the way to the floor sink. | ||
|
|
| • | Do NOT reduce the | |||||
|
| codes. |
|
| |||||
| • | The drainage from the unit to the floor sink is achieved by |
|
|
|
|
|
| |
|
|
|
|
| |||||
|
| gravity only. Make sure that the 1” white PVC tubing is directed |
|
|
|
| Depending on local regulations, you may be required to |
| |
|
| downwards preventing any |
|
|
|
| install a second check valve or pressure reducing back- |
| |
|
| Health Departments require you to terminate the drainage tube |
|
|
|
| flow preventive device. |
| |
|
| 4 in. above the highest point of the |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
Printed in USA 0404 © 2004 | 2 |