ProForm PFTL79008.0 manual Turn if the walking belt has shifted to the right

Models: PFTL79008.0

1 32
Download 32 pages 14.73 Kb
Page 24
Image 24

PROBLEM: The walking belt is off-center or slips when walked on

 

 

 

SOLUTION: a. If the walking belt is off-center, first remove the

a

 

 

key and UNPLUG THE POWER CORD. If the

 

 

walking belt has shifted to the left, use the hex

 

 

 

key to turn the left idler roller bolt clockwise 1/2 of a

 

 

 

turn; if the walking belt has shifted to the right,

 

 

 

turn the idler roller bolt counterclockwise 1/2 of a

 

 

 

turn. Be careful not to overtighten the walking belt.

 

 

 

Then, plug in the power cord, insert the key, and

 

 

 

run the treadmill for a few minutes. Repeat until the

 

 

 

walking belt is centered.

 

 

 

 

b. If the walking belt slips when walked on, first re-

b

 

 

move the key and UNPLUG THE POWER CORD.

 

 

Using the hex key, turn both idler roller bolts clock-

 

 

 

wise, 1/4 of a turn. When the walking belt is cor-

 

 

 

rectly tightened, you should be able to lift each

 

 

 

edge of the walking belt 2 to 3 in. (5 to 7 cm) off

 

 

 

the walking platform. Be careful to keep the walk-

 

 

 

ing belt centered. Then, plug in the power cord, in-

 

 

 

sert the key, and carefully walk on the treadmill for

 

 

 

a few minutes. Repeat until the walking belt is

 

 

 

properly tightened.

 

 

 

 

PROBLEM: The crosswalk arms squeak during use

 

 

 

 

SOLUTION: a. (Note: Correcting this problem re-

a

 

 

 

quires a small amount of white ma-

 

 

 

rine grease, available at hardware

 

 

 

 

stores.) Remove the Resistance

 

77

 

 

Knob (88) from the resistance as-

 

 

 

sembly. Remove the resistance as-

88

 

 

92

sembly from the Left Upright (77) or

85

Resistance

the Right Upright (92).

 

 

 

 

Assembly

 

Apply a small amount of grease

 

 

 

 

around the Resistance Cone (85).

 

 

 

 

Insert the resistance assembly into

 

 

 

 

the Left Upright (77) or the Right

 

 

 

 

Upright (92). Then, tighten the

 

 

 

 

Resistance Knob (88) onto the re-

 

 

 

 

sistance assembly.

 

 

 

 

24

Page 24
Image 24
ProForm PFTL79008.0 manual Turn if the walking belt has shifted to the right, Problem The crosswalk arms squeak during use