Installation & Operating Instructions
Owner’s Reference PowerPack 1500 MKII
Restore electrical power to connected equipment by re-plugging the UPS power
cord into a wall outlet
Press and hold both the main on switch “I” and the main off switch “ ” on the
front panel for more than 3 seconds while the UPS is in the off status. The UPS
will now enter parameter conguration mode.
• When the UPS enters into the configuration mode, the turn on of six different
status indicator LEDs represent different parameter being programmed.
• Different parameter can be selected by pressing and holding the main off
switch “ ” for more than 3 seconds.
•Different settings can be selected by pressing and holding the main on switch
“I” for more than 3 seconds.
• To Exit the configuration mode:
Press and hold both the main on switch “I” and off switch “ ” for more than 3
seconds.