B – Command Line Interface
Set Config Command
B-34 59021-06 A
D
Table B-11. Set Config Threshold Parameters Parameter Description
Threshold Monitoring Enabled Master enable/disable parameter for all
events. Enables (True) or disables (False)
the generation of all enabled event alarms.
The default is False.
CRCErrorsMonitoringEnabled
DecodeErrorsMonitoringEnabled
ISLMonitoringEnabled
LoginMonitoringEnabled
LogoutMonitoringEnabled
LOSMonitoringEnabled
The event type enable/disable parameter.
Enables (True) or disables (False) the
generation of alarms for each of the
following events:
CRC errors
Decode errors
ISL connection count
Device login errors
Device logout errors
Loss-of-signal errors
Rising Trigger The event count above which a rising
threshold alarm is logged. The switch will
not generate another rising threshold
alarm for that event until the count
descends below the falling threshold and
again exceeds the rising threshold.
Falling Trigger The event count below which a falling
threshold alarm is logged. The switch will
not generate another falling threshold
alarm for that event until the count
exceeds the rising threshold and
descends again below the falling
threshold.
Sample Window The period of time in seconds in which to
count events.