Environmental
A-4 59021-06 A
D
A.6
Environmental
Temperature
Operating..................................
Non-operating...........................
10 to 40°C (50 to 104°F)
-40 to 65°C (-40 to 149°F)
Humidity
Operating..................................
Non-operating...........................
25% to 80%, non-condensing
25% to 90%, non-condensing
Altitude
Operating..................................
Non-operating...........................
0 to 3048m (0 to 10,000 feet)
0 to 15,240m (0 to 50,000 feet)
Vibration
Operating..................................
Non-operating...........................
Magnitude during/after along any axis
2.54 mm (.1); 5 - 14 Hz
0.1G; 14-300 Hz
5 - 500 Hz, random
2.09 G rms, 10 minutes
Shock
Operating..................................
Non-operating...........................
Magnitude during/after along any axis
1 g for 15 msec
8 g for 15 msec
Air flow............................................ Two fans; front-to-back or back-to-front by
model