Q-Logic 9100, 59229-05 A manual Exiting the Maintenance Menu, Unpacking a Firmware Image File

Models: 59229-05 A 9100

1 168
Download 168 pages 11.42 Kb
Page 110
Image 110

4–Diagnostics/Troubleshooting

Recovering a Switch Using Maintenance Mode

5.The maintenance menu displays several recovery options. To select a switch recovery option, press the corresponding number (displayed in option: field) on the keyboard and press the Enter key.

0)Exit

1)Image Unpack

2)Reset Network Config

3)Reset User Accounts to Default

4)Copy Log Files

5)Remove Switch Config

6)Remake Filesystem

7)Reset Blade

Option:

Exiting the Maintenance Menu

This option closes the current login and Telnet session. To log in again, enter the maintenance mode account name and password (prom, prom). To return to normal operation, power cycle the switch.

Unpacking a Firmware Image File

This option unpacks and installs new firmware when the current firmware has become corrupt. Before using this option, you must load the new firmware image file onto the switch. To install new firmware using this option do the following:

1.Enter the FTP command and the switch IP address or symbolic name.

>ftp 10.0.0.1

2.When prompted for a user and password, enter the FTP account name and password (images, images).

user:images password: images

3.Set binary mode and use the Put command to upload the firmware image file (7.8.xx.xx_ThCP).

ftp>put 7.8.xx.xx_ThCP

xxxxxbytes sent in xx secs.

ftp>quit

4.Place the switch in maintenance mode. Refer to “Recovering a Switch Using Maintenance Mode” on page 4-15for detailed instructions.

5.Establish a Telnet session with the switch using the default IP address 10.0.0.1.

telnet 10.0.0.1

4-16

59229-05 A

Page 110
Image 110
Q-Logic 9100, 59229-05 A manual Exiting the Maintenance Menu, Unpacking a Firmware Image File