2 – InfiniPath Cluster Administration Configuration and Startup

You can check and adjust these BIOS settings using the BIOS Setup Utility. For specific instructions on how to do this, follow the hardware documentation that came with your system.

2.4.2

InfiniPath Driver Startup

The ib_ipath module provides low level InfiniPath hardware support. It does hardware initialization, handles infinipath-specific memory management, and provides services to other InfiniPath and OpenFabrics modules. It provides the management functions for InfiniPath MPI programs, the ipath_ether ethernet emulation, and general OpenFabrics protocols such as IPoIB, and SDP. It also contains a Subnet Management Agent.

The InfiniPath driver software is generally started at system startup under control of these scripts:

/etc/init.d/infinipath

/etc/sysconfig/infinipath

These scripts are configured by the installation. Debug messages are printed with the function name preceding the message.

The cluster administrator does not normally need to be concerned with the configuration parameters. Assuming that all the InfiniPath and OpenFabrics software has been installed, the default settings upon startup will be:

InfiniPath ib_ipath is enabled

InfiniPath ipath_ether is not running until configured

OpenFabrics IPoIB is not running until configured

OpenSM is enabled on startup. Disable it on all nodes except where it will be used as subnet manager.

2.4.3

InfiniPath Driver Software Configuration

The ib_ipath driver has several configuration variables which provide for setting reserved buffers for the software, defining events to create trace records, and setting debug level. See the ib_ipath man page for details.

2.4.4

InfiniPath Driver Filesystem

The InfiniPath driver supplies a filesystem for exporting certain binary statistics to user applications. By default, this filesystem is mounted in the /ipathfs directory when the infinipath script is invoked with the "start" option (e.g. at system startup)

IB6054601-00 D

2-5

Page 23
Image 23
Q-Logic IB6054601-00 D InfiniPath Driver Startup, InfiniPath Driver Software Configuration, InfiniPath Driver Filesystem

IB6054601-00 D specifications

The Q-Logic IB6054601-00 D is a high-performance InfiniBand adapter card designed for data centers and enterprise applications requiring robust connectivity and low-latency communication. This adapter is part of QLogic's extensive portfolio of networking solutions, catering to the needs of high-performance computing (HPC), cloud computing, and virtualization environments.

One of the standout features of the IB6054601-00 D is its capability to support data transfer rates of up to 56 Gbps. This makes it ideal for applications demanding large bandwidth and quick data processing. The adapter is optimized for RDMA (Remote Direct Memory Access) technology, which allows data to be transferred directly between the memory of different computers without involving the CPU. This reduces latency and CPU overhead, leading to enhanced overall system performance.

The architecture of the IB6054601-00 D includes support for a dual-port design, which offers increased bandwidth, redundancy, and fault tolerance. This dual-port configuration is especially advantageous for environments that require high availability and reliability, such as financial services and mission-critical applications.

The adapter utilizes advanced error detection and correction mechanisms, ensuring that data integrity is maintained during transmission. With features like adaptive routing and congestion management, the IB6054601-00 D is capable of optimizing the handling of data flows, thereby enhancing performance even under heavy loads.

In terms of compatibility, the Q-Logic IB6054601-00 D supports a wide range of operating systems and virtualization technologies, making it easy to integrate into diverse IT environments. It also includes drivers and software packages that facilitate seamless deployment and management.

In addition to high-speed connectivity, the adapter is designed with power efficiency in mind. It adheres to Energy Star regulations, helping organizations lower their operational costs while minimizing their environmental footprint.

Overall, the Q-Logic IB6054601-00 D stands out for its high throughput, low latency, and reliability. Its combination of advanced features and technologies positions it as an excellent choice for organizations looking to enhance their data center performance and maximize the efficiency of their network infrastructure. With the growing demands for faster and more efficient data transfer, solutions like the IB6054601-00 D are essential in meeting the evolving needs of modern enterprises.