Configuration Settings | A – Fast!UTIL |
■SCSI termination
Termination for the QLA12160 board can be set in one of three ways:
❑Automatic (default)
❑Manual (through Fast!UTIL)
❑Jumpers
NOTE: The last SCSI device on each end of the SCSI bus must be terminated.
The QLA12160 board is a
Table A-4. QLA12160 Ports
Port | QLA12160 Port |
Connector | |
|
|
One | J1 and J3 |
Two | J2 |
|
|
The following text explains automatic and manual termination. See section B.2 for jumper termination instructions.
❑Auto. SCSI termination requirements are sensed by the board and set automatically. The default is Auto.
With QLA12160 boards, the Auto setting assumes that port one is at one end of the SCSI bus and enables termination for port one. If you are using a single
❑Enabled. This setting overrides termination requirements sensed by the board, assumes that the selected port is at one end of the SCSI bus, and enables termination.
❑Disabled. SCSI termination is disabled. This setting overrides termination requirements sensed by the board. Use this setting when J1, J2, or J3 is not at one end of the SCSI bus. For example, use this setting when you have wide devices daisy chained to the QLA12160 J1, J2, or J3 connector with a single cable and the J1, J2, or J3 connector is not at the end of the cable.
❑High Only. High termination is enabled. This setting overrides termination requirements sensed by the board.
Use this setting for the QLA12160 board’s port one (J1 or J3) when you have a wide device connected to one connector and a narrow device