ASH REMOVAL SYSTEM OPERATING AND CLEANING

ASH REMOVAL SYSTEM OPERATING AND CLEANING

CAUTION: Do not operate stove with ash removal system door open. Store ash in metal container until hot embers have cooled completely.

1.When stove is cool, open front door and brush most of the ash into the center of the firebox. Remember to leave ¼” to ½” (6-13mm) of ash on the firebox floor to act as a natural grate, allowing air to flow freely underneath wood.

2.Clean ash down through the ash removal system grate into the drawer below. If there are large pieces in the ashes, you can remove the grate before cleaning the ash into the drawer. Be sure to replace the grate before operating the stove.

3.Release catches on sides of ash removal door.

4.Pull out ash drawer. Close ash removal door. (Closing this door avoids ash blowing into the room in the event of a downdraft.)

5.Empty ashes into metal container. Store container on non-combustible surface until ashes are cool enough to dispose.

6.Open ash removal door and replace ash drawer, making sure handle faces forward.

7.Close ash removal door and fasten catches.

LEG MODEL

PEDESTAL MODEL