Contents
NorthAmerica’sBest
INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS
QUADRA-FIRE 3100 SERIES
SAVE THESE INSTRUCTIONS
TABLE OF CONTENTS
Model
3100 SAFETY LABEL found on back of stove
Quadra-Fire
Serial No
PEDESTAL MODEL
DIMENSIONS
LEG MODEL
FIGURE 1a
STEP TOP LEG MODEL
STEP TOP PEDESTAL MODEL
DIMENSIONS
FIGURE 2a
CLEARANCES TO COMBUSTIBLES UL AND ULC
INSTALLATION MATERIALS NEEDED FOR YOUR SAFETY
SAFETY LISTING
VENTING SYSTEM
CHIMNEY SYSTEMS
CONNECTION TO A MASONRY CHIMNEY
CHIMNEY CONNECTOR
CHIMNEY HEIGHT/DRAFT
The chimney must have a fire clay flue liner or equivalent with a minimum thickness of 5/8” 16mm and must be installed with refractory mortar. There must be at least ½” 13mm air space between the flue liner and the chimney wall Figure 4. An equivalent liner must be a listed chimney liner system or other approved material
Remember that insulation must not contact the chimney. There must be air space around the chimney. Insulation must be 2” 50mm or more from the chimney Figure
2. THIMBLE An approved thimble must be used when the connection from the stove is made through a combustible wall to a masonry chimney. There are several methods you can use for connection through a combustible wall, two of which are illustrated in this manual. For additional methods, consult local building authorities or use the standards set forth in NFPA
B. 6” SOLID PACK CHIMNEY WITH METAL SUPPORTS AS A THIMBLE For the method of installation to a masonry chimney shown in Figures 10 and 11 page 13, it will be necessary to purchase a 6” 152mm inside diameter, 12” 305mm long section of prefabricated listed solid pack chimney to use as a thimble. Purchase a wall spacer, trim collar and wall band that are manufactured to fit the chimney section you purchase. Cut out a 14 ½” 368mm diameter opening in the wall. It may be necessary to cut wall studs and install a header and sill frame to maintain the wall support. The hole in the chimney must have at least a 6” 152mm diameter fire clay liner or equivalent, secured with refractory mortar. If it is necessary to cut a hole in the chimney liner, use extreme care to keep it from shattering
Page
INTERIOR CHIMNEY, RUNNING THROUGH CEILING AND ROOF
CONNECTION TO A METAL PREFABRICATED CHIMNEY
MOBILE HOME INSTALLATION
3100 PEDESTAL MODELS
OUTSIDE AIR KIT INSTALLATION
3100 LEG MODELS
FOR INSTALLATION OF ASH REMOVAL SYSTEM, SEE PAGE
PEDESTAL/LEG KIT INSTALLATION
PEDESTAL MODEL
LEG MODEL
LEG MODEL
ASH REMOVAL SYSTEM INSTALLATION
PEDESTAL MODEL
ASH REMOVAL SYSTEM OPERATING AND CLEANING
OPERATING INSTRUCTIONS
IMPORTANT - PLEASE READ BEFORE USING STOVE BURNING PROCESS
BLOWER OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS cont
OPERATING TIPS
BURNING GUIDELINES
BUILDING A FIRE
BURNING GUIDELINES cont
WOOD SELECTION AND STORAGE
OPERATING INSTRUCTIONS cont
CARE AND CLEANING OF GLASS
MAINTENANCE
CARE AND CLEANING OF PLATED SURFACES
CHIMNEY CLEANING
GLASS REPLACEMENT
DOOR HANDLE ASSEMBLY
BAFFLE REMOVAL AND INSTALLATION
BRICK PATTERN
BAFFLE REMOVAL AND INSTALLATION cont
7. Keep the baffle tilted as you lift it out the door
832-0550 Single brick 832-3010 Brick set
BLOWER SWITCH ADJUSTMENTS
INSTALLATION OF OPTIONAL BLOWER
STEPS FOR ADJUSTING THE BLOWER SPEED CONTROL
831-1700
4. Install chimney pipe through hole in top heat shield
TOP HEAT SHIELD INSTALLATION
1. Unscrew and remove the rear heat deflector
3. Set top heat shield on stove and push down into “S” clips
SERVICE PARTS
ACCESSORIES AND SERVICE PARTS
ACCESSORIES
Page
Page
FOR YOUR RECORDS
lifetime warranty
NorthAmerica’sBest