B. Blower Cord Location

The 5100-I Insert comes standard with 2 blowers, installed at the factory with the power cord on right side of insert (as you face the unit). Do not route the power cord under or in front of appliance.

The power cord can also be installed on the left side. Follow instructions below.

Green grounding wire

White wire into Red Connector

 

Black wire into Blue Connector

 

Left Blower

 

Snap Disc

Right Blower

 

Red

 

Connector

Snap Disc

Blue

by-pass

Connector

switch

 

Speed Control

 

(Rheostat)

Figure 12.1 - Blower Assembly Components

1.Disconnect the appliance from power supply.

2.Remove the grille following instructions on page 11.

3.Unplug the blower cord wires from the wire harness.

4.Remove green grounding wire from grounding screw.

5.Using a pair of pliers, squeeze the strain relief and remove the blower cord wires and strain relief from the grille.

6.Locate the wire harness wires tucked up under the ash- catcher on the left side of the appliance. Cut the zip tie that is holding the wires in place.

7.Remove the button plug from the left side of grille. Thread the blower cords wires through the hole and snap the strain relief in place. Figure 12.3.

8.Attach grounding wire to ground screw.

9.Connect the white blower cord wire to the red connector on the wire harness.

10.Connect the black blower cord wire to the blue connec- tor on the wire harness.

11.Tuck the wire out of the way of the blower motor.

12.Re-install grille.

NOTE: Each wire has a label to denote which component it connects to.

 

 

 

 

Blower cord attached to

 

 

 

 

right side of grille.

 

 

 

 

Strain Relief

Bottom

ofgrille

Blower cord

 

 

 

 

 

 

 

 

Green

 

 

 

 

grounding wire

 

 

 

 

White wire

 

 

 

 

Grounding

 

 

of

grille

screw

Top

Black wire

 

 

 

 

 

 

 

Back view of grille

Figure 12.2

 

Remove button plug

grille

 

of

 

Bottom

 

grille

Grounding screw

 

of

 

Top

Back view of left

 

 

side of grille

Figure 12.3

Caution

Shock hazard.

• Do NOT remove grounding prong from plug.

Plug directly into properly grounded 3 prong receptacle.

Route cord away from appliance.

Do NOT route cord under or in front of appli- ance.