5100-I ACT WOOD INSERT

R

 

 

 

 

 

10

 

 

With proper installation, operation, and maintenance your appliance

 

 

 

 

 

 

 

 

 

 

 

 

provide years of trouble-free service. If you do experience a problem,

 

 

 

 

Troubleshooting

this troubleshooting guide will assist a qualified service person in the

 

 

 

 

diagnosis of a problem and the corrective action to be taken.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start Fire Problems

Possible Cause

Solution

 

 

 

 

 

 

 

 

 

Can’t get fire started

Not enough kindling/paper or no

Use dry kindling, more paper. Arrange kindling &

 

 

 

Excessive smoke or

kindling/paper

 

wood for air movement.

 

 

 

spillage

 

 

 

 

 

 

 

 

Not enough air for fire to ignite

Check for restricted cap/shroud

 

 

 

Burns too slowly

 

 

 

 

 

 

 

 

 

 

 

Smolders, sizzles

 

 

 

 

 

 

 

 

 

 

 

 

Check for flue blockage.

 

 

 

 

 

 

 

 

Pre-warm flue before starting fire (refer to starting

 

 

 

 

 

 

 

 

fire section).

 

 

 

 

 

 

 

 

Check for adequate vent height (refer to chimney

 

 

 

 

 

 

 

 

assembly section).

 

 

 

 

 

 

 

 

Open window below the appliance towards the

 

 

 

 

 

 

 

 

wind.

 

 

 

 

 

 

Wood condition is too wet, too

Use dry, seasoned wood (refer to wood fuel

 

 

 

 

 

 

large

 

section).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bed of coals not established

Start with paper & kindling to establish bed of coals

 

 

 

 

 

 

before adding wood

(refer to starting fire section).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flue blockage such as birds’ nests

Have chimney inspected for creosote and cleaned

 

 

 

 

 

 

or leaves in termination cap

by a certified chimney sweep.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Down draft or negative pressure

Do not use exhaust fans during start-up (refer to

 

 

 

 

 

 

Competition with exhaust devices

negative pressure section).

 

 

 

 

 

 

 

 

Open window below the appliance towards the

 

 

 

 

 

 

 

 

wind.

 

 

 

Fire burns too fast

 

Extremely dry or soft wood

 

 

 

 

 

 

 

 

 

Mix in less seasoned wood after fire is established

 

 

 

 

 

 

 

 

(refer to wood fuel section).

 

 

 

 

 

 

Overdrafting

 

Check for correct vent height; too much vertical

 

 

 

 

 

 

 

 

height creates overdrafting.

 

 

 

 

 

 

 

 

Check location of vent termination (refer to chimney

 

 

 

 

 

 

 

 

 

 

 

April 21, 2010

438-0380E

Page 37