R

5100-I ACT WOOD INSERT

E. Metal Heat Circulating Masonry

This insert conforms with the safety standard UL-1482 and ULC S628 (Canada) in all respects and is approved to UL & ULC safety standards for installation and use within a fire- place with masonry chimney, in accordance with NFPA 211, with a direct flue collar connection.

•The original factory-built clearance fireplace chimney cap must be re-installed after installing the approved chimney liner meeting type UL 103 HT requirements (2100°F) per UL 1777.

•If the chimney is not listed as meeting HT requirements, or if the factory built fireplace was tested prior to 1998, a full height listed chimney liner must be installed from the appliance flue collar to the chimney top.

F. Prefabricated Metal Chimney

The chimney can be new or existing, masonry or prefabricated and must meet the following minimum requirements:

•Must be minimum 6 inch (152mm) inside diameter of high temperature chimney listed to UL 103 HT (2100oF) or ULC S628.

•Must use components required by the manufacturer for installation.

•Must maintain clearances required by the manufacturer for installation.

•Refer to manufacturers instructions for installation

•This insert is listed to UL 1482 Standard and is approved for installation into listed factory-built zero clearance fireplaces listed to UL 127 conforming to the following specifications and instructions:

•The liner must be securely attached to the insert flue collar and the chimney top.

•The air flow of the factory-built zero-clearance fireplace system must not be altered. The flue liner top support attachment must not reduce the air flow for the existing air-cooled chimney system.

•No dilution air is allowed to enter the chimney.

1.Secure the fireplace damper in the open position. If this cannot be accomplished, it will be necessary to remove the damper

2.Seal damper area of chimney around chimney connector with a high temperature sealant or seal insert against the face of the fireplace.

3.Both methods must be removable and replaceable for cleaning and re-installation.

Flue Liner with Required Air Space

 

Stainless Steel Chimney Connector

 

Must Extend to Flue Liner

 

Minimum 8” (203mm) Masonry Thickness

 

in Front of Smoke Chamber

 

 

Airtight Insulated Clean-Out

Minimum Clearance in Accordance with

 

Insert Listing

Damper Plate Removed or

 

 

Fastened in Open Position

Floor Protection in

 

Accordance with Insert

Seal with Non-

Listing

Combustible Material

 

Combustible Floor

 

Figure 16.1

Page 16

438-0380E

April 21, 2010

Page 16
Image 16
Quadra-Fire 5100I-NL-B, 5100I-GD-B warranty Metal Heat Circulating Masonry, Prefabricated Metal Chimney