Models: 5100I-GD-B 5100I-NL-B

1 44
Download 44 pages 14.54 Kb
Page 34
Image 34

R

5100-I ACT WOOD INSERT

E.Door Handle Assembly Replacement

Frequency: As needed

By: Homeowner / Qualified service technician

Task: See the following instructions.

1.Install washer on door handle shaft.

2.Slide door handle through door.

3.Install second washer(s) as shown.

4.Install key in groove.

5.Align groove in latch cam with key; slide latch cam over shaft

6.Install locknut.

7.Install spring handle turning in a counter-clockwise motion to desired location on handle.

F. Blower Replacement

Frequency: As needed

By: Homeowner / Qualified service technician

Task: See the following instructions.

1.Remove the panel and trim set. See pages 21-22for complete details.

2.Remove 2 screws on blower housing.

3.Unhook the wires from the blower.

4.Slide blower housing out.

5.Remove 2 screws from blower and remove from housing.

6.Attach new blower to housing.

7.Re-assemble in reverse order.

Latch Cam

Door Cross

Section

 

Locknut

Spring Handle

Door Handle

Spacing Washers

Square Key

Figure 34.1

CAUTION

Do NOT overtighten lock nut.

Door handle needs to move smoothly.

Remove

2 Screws

Figure 34.2

Figure 34.3

Page 34