4. Existing Masonry Chimney

Type A - Up & Out Installations for Top Vent Configurations

 

 

 

 

 

 

 

 

TERMINATION

TOP ADAPTOR

 

 

 

 

 

 

 

CAP

 

 

 

 

 

 

 

 

 

 

 

 

 

FLASHING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RETRO CONNECTOR

4 in. (102mm)

 

FLEX LINER

90° ELBOW

 

DIRECT VENT PIPE

Type B - Hearth Rear Vent Installations for Use With Rear Vent Kit (see Section 12 for conversion kit and venting components.)

Chimney Liner

Termination Cap

Part #923GK

Co-Axial to

 

Co-Linear

3 in. (76mm)

Connector

Part #923GCL

FLEX LINER

PIPE LENGTH

OPTIONAL

Figure 5.24

Co-Axial to

Co-Linear

Connector

Part #923GCL

Pipe Length

Optional

Chimney Liner

Termination Cap

Part #923GK

30 ft. (9m) of 3 in. (76mm) Flex Liner Exhaust Section

This section of the chimney must be sealed

The chimney must be sealed from the 4 ft. (1m) section to termination using a smoke shelf or a damper. (In the Commonwealth of

Massachusetts, the word damper shall be replaced with the words flue restrictor.) The seal should be 6 in. (152mm) below the end of the 4 ft. (1m) Air Intake section.

4 ft. (1m) of 3 in.

(76mm) Flex Liner Air Intake Section

 

 

 

 