I. Glass Door Assembly Replacement

Remove the glass door assembly by opening latches at the bottom front of the appliance, on both the left and right sides. Lift out and away from the appliance.

Replace with a new glass door assembly.

CAUTION

Handle glass assembly with care.

Inspect the gasket to ensure it is undamaged.

Inspect the glass for cracks, chips or scratches.

Do NOT strike, slam or scratch glass.

Do NOT operate appliance with glass door removed, cracked, broken or scratched.

Replace glass assembly as a complete assembly.

Figure 8.28 Connect electrical connector to snap disc.

J. Blower Installation

FROM THE KIT YOU WILL NEED: Blower motor; snap disc bracket with wire harness; rheostat, rheostat nut; knob; screws; 1 zip-tie.

TOOLS REQUIRED: #2 Phillips head bit; hand drill; 11/16 in. wrench; and a 5/16 in. wrench.

Figure 8.29 Install speed control to switch panel. Attach knob to speed control.

Attach with 4 screws

Figure 8.26 Turn off gas supply, (if gas is connected,) and remove rear shield. Remove blower from packaging. Place blower under appliance. Attach blower from front with 4 screws to blower bracket.

5/16 in. nut

Snap Disc Bracket

Figure 8.30 Reinstall rear shield. Connect blower to power supply and turn on gas supply.

NOTE: This blower utilizes a snap disc to control ON and OFF operation. When the correct temperature is reached, the blower will automatically turn ON. Use the rheostat knob to adjust the fan to High or Low to suit your preferences.

Figure 8.27 Install snap disc in bracket. Attach bracket to fire- box with 5/16 in. wrench.

 

 

 

 