3

Appliance Location and Clearances

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

 

WARNING

 

· Illustrations reflect typical installations and are FOR

 

 

 

Fire Risk

DESIGN PURPOSES ONLY.

· Illustrations/diagrams are not drawn to scale.

Provide adequate clearance:

Around air openings

· Actual installation may vary due to individual design

To combustibles

preference.

For service access

Locate appliance away from traffic areas.

A. Selecting Appliance Location

When selecting a location for your appliance it is important to consider the required clearances to walls (see Figure 3.1).

B. Clearances

WARNING

Fire Risk.

Locate and install appliance to all clearance specifications in manual.

 

F

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

C

 

 

 

 

 

G

 

 

 

 

 

 

 

B

 

 

 

 

 

 

A

A

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

A

A

 

 

 

 

C

 

 

 

 

 

Model

 

A

B

C

D

E

F

G

 

 

Topaz

Inches

6-1/2

6

1

54

36

40

23

 

 

 

Millimeters

165

152

25

1372

914

1016

584

 

Figure 3.1

 

 

 

 

 

 

 

 

 

 

It is permissable to place the appliance on carpet.

CAUTION

Some carpet materials may be sensitive to radiant heat from the appliance causing discoloration or odor.

NOTE: Flooring beneath appliance may reach 90 degrees plus room ambient temperature. Check with flooring manufacturer for maximum temperature allowed on flooring surfaces.

WARNING

Fire Risk.

Odor Risk.

Tipping Risk

Install appliance on a stable, level platform/ floor strong enough to support appliance without tipping.

USE wood flooring, ceramic tile, brick hearth or high pressure laminate flooring applied directly over the sub-flooring material.

January 3, 2007

Quadra-Fire · Topaz · 7009-113E

Page 7

Page 7
Image 7