2.1.2.7 Example 7

DEVICE = C:\SSP-100\SSP100CL.SYS (s0,b300,i5) (s1,b340,i10)

The type of configuration shown in example 7 may be desirable in systems where more than one SSP-100 is to be installed. In this example, the Client Driver will attempt to configure a SSP-100 inserted into socket 0 with a base address of 300H and IRQ 5. If the SSP-100 is inserted into socket 1, the Client Driver will attempt to configure it with base address 340H and IRQ 10. This allows the user to force the SSP-100's address and IRQ settings to be socket specific which may simplify cable connections and software development. As in the previous examples, however, if the requested address or interrupt resources are not available, the SSP-100 will not be configured.

2.1.2.8 Example 8

DEVICE=C:\SSP-100\SSP100CL.SYS (s0,b300,i5,e3)

In Example 8, the Client Driver will attempt to configure an SSP-100 into socket 0 with a base address of 300H and IRQ 5. The COM 3 spot of the BIOS Equipment list will be occupied with the SSP-100. If the requested socket, base address or interrupt resources are not available, the SSP-100 will not be configured and no update of the equipment list will take place. If the requested spot in the BIOS equipment list is not available, but the requested socket, base address, and IRQ are available, the SSP-100 will be configured but an error message will appear stating that no update of the equipment list can take place.

2.1.2.9 Example 9

DEVICE=C:\SSP-100\SSP100CL.SYS (s0,a3)

In Example 9, the Client Driver will attempt to configure an SSP-100 into socket 0 with the COM 3 standard address of 3E8H and IRQ 4. The COM 3 spot of the BIOS equipment list will be updated automatically. If the requested socket is unavailable, or the COM 3 resource settings are unavailable, the SSP-100 will not be configured and no update of the BIOS equipment list will be made. If the requested spot in the BIOS equipment list is not available, but the requested socket, base address, and IRQ are available, the SSP-100 will be configured but an error message will appear stating that no update of the equipment list can take place.

SSP-100 User’s Manual

2-6

Page 15
Image 15
Quatech user manual Device = C\SSP-100\SSP100CL.SYS s0,b300,i5 s1,b340,i10