Quatech SSP-100 user manual Advanced Configuration Topics

Models: SSP-100

1 51
Download 51 pages 36.92 Kb
Page 45
Image 45

5.1.2.2 Example 2

DEVICE=C:\SSP-100\SSP100.SYS (7,120,15) (3,300,4)

In example 2, the Client Driver will attempt to configure the SSP-100 as COM3 using I/O address 300-307 hex and IRQ 4. If COM3 already exists, or if the I/O address or IRQ resources are already in use, the Client Driver will attempt to configure the SSP-100 as COM7 using I/O address 120-127 hex and IRQ 15. If COM7 already exists or if the I/O address or IRQ resources are already in use, the SSP-100 will not be configured. Up to two SSP-100s can be installed in this system.

5.1.3 Advanced Configuration Topics

For some applications, it may be desirable to specify the resources for one SSP-100 while allowing the OS/2 Plug-and-Play system to assign the hardware resources for any additional cards. This can be accomplished by mixing the configuration methods on the SSP-100 Client Driver command line

DEVICE=C:\SSP-100\SSP100.SYS (3,100,5) COM7

It is important to remember that when a SSP-100 is inserted into a PCMCIA socket, the client driver will configure the card as a series of COM ports, starting with the lowest available port number in the list.

Another common application requirement is to have a SSP-100 inserted into socket 1 be configured as COM3 while a SSP-100 inserted into socket 2 be configured as COM7 . This type of configuration is supported by appending a "=Sx" parameter after any command line argument.

DEVICE=C:\SSP-100\SSP100.SYS COM3=S1 COM7=S2

DEVICE=C:\SSP-100\SSP100.SYS (3,100,4)=S1 (7,300,3)=S2

SSP-100 User's Manual

4-7

Page 45
Image 45
Quatech SSP-100 user manual Advanced Configuration Topics