Section Seven: Before Calling for Service
DO-IT-YOURSELF MAINTENANCE
POWER FAILURE
In the event of a power failure,only the standard
If the cooktop is being used when the power failure occurs, turn all of the burner control knobs to the OFF position. Then, the standard
burners and grill can be lighted by holding a match at the ports and turning the control knob to the Hl position. Wait until the flame is burning all the way around the burner cap before adjusting the flame to the desired height.
The two ExtraLow® burners on the far left side cannot be used
during a power failure. Be sure to turn them OFF if a power failure occurs.They will not turn back on until both control knobs are first turned OFF and then turned back on again.The griddle and wok can- not be used during a power fail- ure. See WhatTo Do IfYou Smell Gas, inside front cover.
INTERMITTENT OR CONSTANT IGNITER SPARKING
Intermittent or constant sparking of the sealed gas surface burners can result from a number of preventable conditions. Eliminate these conditions as indicated in the chart.
SYMPTOM | CAUSE | REMEDY |
Intermittent sparking | • Improper fit of burner cap into | • Seat cap in place. |
| burner base |
|
| • Ceramic igniter is wet or dirty. | • Carefully dry or clean igniter. |
| • Burner ports are clogged. | • Clean ports in burner cap with a |
|
| wire, a needle or straightened |
|
| paper clip. |
(Wok) | • Knob is left in the LITE position | • Turn Wok knob to a setting |
|
| between Hl and LO. |
|
|
|
Constant Sparking | • Cooktop is not properly grounded. | • Have a qualified electrician |
| • Electrical power supply is | ground the cooktop properly. |
| incorrectly polarized. | Refer to Installation Instructions. |
|
| • Refer to Installation Instructions |
|
| for correct installation. |
|
|
|