Ventilation

INSTALLATION

Ventilation

The appliance housing used must provide adequate ventilation in accordance with the manufacturer’s recommendations as detailed in the installation diagrams above.

For built-in installation, a minimum ventilation cut-out of 400cm2 must be incorporated into the support shelf beneath the oven together with a 500mm

x15mm cut-out along the upper edge of the housing unit’s plinth. A further ventilation space of 50mm must exist between the rear of the appliance and the back of the housing or an adjacent wall.

If a tall housing is to be installed flush with the ceiling, a 20cm2 ventilation cut- out must be provided at the top of the housing.

When placing the oven in the housing, do not use the oven door as a lever for lifting the oven as damage may result.

Once the oven has been positioned in the housing it should be secured in place at the four corners of the oven door frame using suitable screws (see diagram).