WARNING SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
Conversion to LP gas
Check in the Technical Data section at the back of the book that the cooker is convertible to the gas you want to use.
This conversion must be performed by a competent person. After conversion the installation must comply with the relevant regulations and also the local electricity supply company requirements. Read the instructions before converting this appliance.
Failure to convert the appliance correctly could invalidate any warranty or liability claims and lead to prosecution.
This instruction must be used in conjunction with the rest of the appliance instruction, in particular for information on Standards, cooker positioning, connection hose suitability etc.
When servicing or replacing
Do not use
Disconnect from the electricity supply before commencing servicing. Before electrical re- connection, check that the appliance is electrically safe.
Injectors
Remove burner caps and heads. Remove old jets. Fit the new jets (see Technical Data section at the back of the book for correct jets). Reassemble in reverse order.
Tap adjustment
Disconnect from electricity supply.
Pull off all the control knobs.
Open the grill and right hand oven doors and remove the 4 fixing screws underneath the control panel.
Remove the handrail by removing the 2 end bracket fixing screws.
Remove the 2
The control panel should drop down slightly. It is held at the top by two holes in the top edge one at each end that locate on tags on the inner panel.
Clear the holes from the inner panel and pull the control panel forward.
Take care not to damage or strain the wiring.
To convert to LP gas.
Turn the bypass screw on each control clockwise to the stop.
Refit the control panel. Locate the holes in the top edge on the tags on the inner panel and replace the fixing screws in the bottom edge.
Replace the hand rail.
30