We will do everything possible to return your unit as quickly as possible. To inquire about the status of your unit our Product Repair Centre may be reached by calling
Please keep a record of the serial number of your unit and have this number ready when you call.
5.2 PREVENTATIVE MAINTENANCE
The procedures listed below for the RAY 210 should be performed at monthly intervals to minimize the possibility of an equipment failure and assure optimum performance.
1.Inspect the antenna system. Pay particular attention to the cleanliness of the antenna connectors and the condition of any soldered connections.
2.Fuse holders and their connections may be subject to corrosion which can increase circuit resistance. The
3.The radio front panel should be cleaned with a tissue or a soft
CAUTION Do not use solvents or other chemicals for cleaning this equipment. NOTE: The following alignment procedures have been provided in this manual to aid FCC licensed technicians and service personnel only.
5.3 ALIGNMENTS AND SERVICE
The RAY 210 is completely aligned at the factory and normally does not require any readjustment at installation. However, it is considered good a practice to verify the power output, modulation, and receiver performance on occasion.
The test equipment listed in paragraph 5.3.1 is used for the test setup shown in Figure
31