WATER TEMPERATURE SENSOR INSTALLATION

POOL HEATING INSTALLATIONS

Fig. # 9498

Fig. # 9499

1.Install the air temperature sensor across the air temperature sensor contacts (P2, pins 1 and 2; see the field wiring diagram on pg. 13).

2.On the mode selector switch (S3), set switch #2 (Outdoor Reset) to ON to disable the outdoor reset function. (See pg.s 15 and 23).

3.Set the Outdoor Cutoff Temperature to 200°F. (See pg. 21.)

4.Adjust the setpoint to desired pool temperature. Thereafter, the controller will track the setpoint and fire heater stages as necessary.

NOTE: The Outdoor Air Temperature sensor can be used as a replacement for the Water Temperature Sensor, as both sensors are indicated.

12

Page 12
Image 12
Raypak 240692 manual Pool Heating Installations