CONNECTIONS - PLUMBING

The table below provides indicative pipe and pump sizes for typical installations

Model

Pump

 

Branch Size

 

Minimum Manifold Header

 

 

 

 

Size Required (mm)

 

 

 

 

 

 

 

 

 

 

UPS

Speed

inches

mm

1

 

2

3

 

4

 

Series

Unit

 

Units

Units

 

Units

 

 

 

 

 

 

109

20-60B

3

1

25

25

 

32

32

 

40

 

 

 

 

 

 

 

 

 

 

 

147

20-60B

3

1

25

20

 

32

32

 

40

 

 

 

 

 

 

 

 

 

 

 

PUMP SELECTION

In order to obtain the best possible water flow in the system a correctly sized pump must be installed. Refer to the Flow Rate and Pressure Drop table below and allow for the system head pressure when sizing the pump.

The pump selected should provide a 10 to 20°C temperature difference between the water heater inlet and outlet when the water heater is at full fire.

Mechanical heating systems with multiple zones may require additional pump(s) refer to ‘Multi Pump Options’ on page 28.

WATER FLOW RATE AND PRESSURE DROP

 

10°C Rise

 

15°C Rise

 

 

20°C Rise

Model

l/sec

kPa

l/sec

kPa

l/sec

kPa

 

 

 

 

 

 

 

109

0.5

5.0

0.4

4.0

0.3

3.0

147

0.8

5.0

0.5

3.0

0.4

3.0

PRESSURE RELIEF VALVE

The pressure relief valve and elbow are shipped in a plastic bag inside the water heater. The pressure relief valve must be fitted before the water heater is operated.

Fit the elbow supplied in the plastic bag to the connection on the inlet/outlet header then screw the relief valve onto the other end of the elbow.

Seal the threads using Teflon tape, never hemp. A drain line must be installed in accordance with AS/NZS 3500.4 to carry the discharge from the valve to a suitable discharge point.

Relief Valve Pressure Rating

On/Off Models

850 kPa (125 psi)

Hi/Lo Models

310 kPa (45 psi)

Pressure

Relief Valve

When the water heater is connected to a storage cylinder for water heating applications, a correctly sized and pressure rated TPR valve MUST be fitted to the storage cylinder.

NOTE: Where a Hi/Lo water heater is used in a water heating application it will be necessary to replace the 310 kPa relief valve provided with the water heater with one rated at 850 kPa.

RELIEF VALVE DRAIN

A copper drain line must be fitted to the relief valve to carry the discharge clear of the water heater. Connect the drain line to the relief valve using a disconnection union. The pipe work from the relief valve to the drain should be as short as possible and fall all the way from the water heater with no restrictions. It should have no more than three right angle bends in it. Use DN20 pipe.

The outlet of the drain line must be in such a position that flow out of the pipe can be easily seen (refer to AS/NZS 3500.4) - but arranged so hot water discharge will not cause injury, damage or nuisance. The drain line must discharge at an outlet or air break not more than 9 metres from the relief valve.

In locations where water pipes are prone to freezing, the drain line must be insulated and not exceed 300 mm in length. In this instance, the drain line is to discharge into a tundish through an air gap of between 75 mm and 150 mm.

WARNING: The pressure relief valve on this water heater may discharge high temperature water under certain conditions, it is strongly recommended the pipe work downstream of the relief valve be capable of carrying water exceeding 93°C. Failure to observe this precaution may result in damage to pipe work and property.

20

Page 20
Image 20
Raypak B0147, B0109 Model Pump Branch Size Minimum Manifold Header, Pump Selection, Relief Valve Pressure Rating

B0109, B0147 specifications

Raypak is a well-established name in the world of heating technology, particularly recognized for its efficient and reliable pool and spa heaters. Among their range, the Raypak B0147 and B0109 models stand out for their performance and advanced features designed to enhance user experience.

Both the Raypak B0147 and B0109 models prioritize efficiency, making them ideal choices for residential or commercial swimming pools. They are engineered to deliver reliable heating, ensuring that water maintains a comfortable temperature no matter the season. One of the standout features is their compact design, which allows for easy installation in various settings without requiring extensive modifications to existing infrastructure.

A key characteristic of the Raypak B0147 is its digital control system. This advanced technology allows users to set precise temperatures and monitor heater performance. The intuitive interface makes it user-friendly, facilitating adjustments on-the-fly. The B0109 model, meanwhile, offers robust heating capabilities, featuring a high-output design that can rapidly elevate water temperatures, perfect for pools with significant heat loss.

Both models utilize a copper-fin-tube heat exchanger, which enhances heat transfer efficiency and extends the lifespan of the heater. This design not only improves thermal efficiency but also ensures that users experience lower energy bills over time. They also come equipped with a dependable ignition system, featuring an automatic spark ignition that eliminates the need for pilot lights, leading to improved safety and reliability.

Durability is another hallmark of the Raypak line. Both models are constructed with materials designed to withstand harsh weather conditions and exposure to pool chemicals, ensuring longevity. The corrosion-resistant housings prevent degradation, maintaining the heater's performance over time.

In summary, the Raypak B0147 and B0109 models deliver outstanding heating performance through efficient technology and durable construction. Their user-friendly controls, compact design, and energy-efficient heat exchangers make them excellent choices for pool owners looking to optimize their heating solutions. With Raypak, users can enjoy comfortable water temperatures year-round, backed by reliable technology and impressive efficiency.