BURNER PRESSURE ADJUSTMENT
GAS INLET PRESSURE
IMPORTANT – CHECK the gas supply pressure at the inlet to the water heater with the water heater and all other gas burning appliances in the premises operating (burners alight). The minimum gas supply pressures are:
Natural Gas - 1.13 kPa | Propane - 2.75 kPa |
If this minimum cannot be achieved, it may indicate the meter or the gas line to the water heater is undersized. It is important to ensure that an adequate gas supply pressure is available to the water heater when other gas burning appliances, on the same gas supply, are operating.
GAS PRESSURE ADJUSTMENT 109 On/Off Models
To adjust the burner pressure on a water heater with a White Rodgers 36G22 Type 210 gas valve proceed as follows:
•Remove the screw from the outlet pressure tap.
•Attach a manometer to the outlet pressure tap.
•Remove the cap from the pressure regulator adjuster.
•With the main burner operating, adjust the pressure regulator (clockwise to increase or
•Turn off the water heater.
• | Replace the cap on the pressure regulator adjuster. | Regulator Cap | |
Pressure Tap | |||
|
|
•Disconnect the manometer and replace the pressure tap screw and washer.
•Check for gas leaks, using soapy water.
147 On/Off Models |
|
|
To adjust the burner pressure on a water heater with a Honeywell Smart | Regulator Cap | Pressure Tap |
Valve, proceed as follows: |
•Remove the screw and washer from the outlet pressure tap.
•Attach a manometer to the outlet pressure tap.
•Remove the cap from the pressure regulator adjuster.
•With the main burner operating, adjust the pressure regulator (clockwise to increase or
•Turn off the water heater.
•Replace the cap on the pressure regulator adjuster.
•Disconnect the manometer and replace the pressure tap screw and washer.
•Check for gas leaks, using soapy water.