SECTION 4 / SERVICING INSTRUCTIONS

GENERAL LOCATION OF CONTROLS

 

Bypass

Drain Plug

Hi Limit

(Located

(Located in

in Return

Return

Header)

Header)

 

Ignition

AGS Hi-

Limit

Control (IID)

(Located

 

Digital

in Inlet/

Oulet

 

Thermostat

Header)

 

Module

Unitherm

 

Roll-Out

Governor

 

Switch

Drain Plug

 

Gas Valve

On-Off Switch

Pilot

Transformer

 

Fig #2005

CONTROL PANEL REMOVAL

1.Remove (4) screws from sides of control panel.

2.Rotate control panel down until panel stops. Do not force.

NOTE: Caution must be taken not to damage controls or wiring.

Control Panel

Mounting Screws (4)

Fig. #RP 8267

CONTROLS/ADJUSTMENTS/REPLACEMENTS

Temperature

Adjust Buttons

Mode Button

LCD Display

Fig. #2000

MILLIVOLT CONTROLS

The pool or spa water temperature is controlled by the pool heater thermostat on the upper front panel of the heater. The control center contains an On/Off switch and one or two thermostats.

Thermostats are fitted with a means of limiting the upper temperature limit below the maximum level. The knob stop adjustment ring illustrated below is adjustable by loosening the set screw, rotating the knobstop ring to the desired location and retightening the set screw.

SPA TEMPERATURE RANGE POOL TEMPERATURE RANGE

STAND-BY

TEMPRATURE

SET SCREW

KNOB STOP RING

Fig. #8103.2

KNOB STOP SHOWN ABOVE IS

IN THE SPA TEMPERATURE RANGE

25

Page 25
Image 25
Raypak P-R405A General Location of Controls, Control Panel Removal, Controls/Adjustments/Replacements, Millivolt Controls